-40%

Tempstar RAV060H0FA0AAAA 5 Ton 11.2 EER A/C Package Unit, 208-230/3/60, R-410A

$ 3960

Availability: 99 in stock
  • Unit Type: Unit
  • Number of Compressors: 1
  • Type: Packaged/Rooftop Air Conditioner Unit
  • Condition: New
  • Energy Efficiency Ratio (EER): 11.1-12
  • Voltage: 208/230 V
  • Model: RAV060H0FA0AAAA
  • Brand: Tempstar
  • Power Phase: 3 Phase
  • Compressor Type: Scroll
  • Power Source: Corded Electric
  • Number of Fan Motors: 1

    Description

    RAV060H0FA0AAAA
    Description
    SINGLE PACKAGE ROOFTOP UNITS WITH X-VANE™ FAN TECHNOLOGY:
    GAS HEATING/ELECTRIC COOLING (RGV) 3 - 6 TON
    AND ELECTRIC COOLING/OPTIONAL ELECTRIC HEAT (RAV) 3 - 6 TON
    K = 208/230-1-60, H = 208/230-3-60, L = 460-3-60, S = 575-3-60
    The new 3 to 6 Ton RGV/RAV series rooftop units (RTU) with X-Vane™ Fan Technology provides value added benefits never seen in this type of equipment before. New major design features include:
    Patent pending, the industry’s first beltless direct-drive vane axial fan for rooftop units with electric commutated variable speed motor.
    Reliable fixed speed scroll compressor on 3-5 ton sizes and 2 stage scroll technology on 6 ton sizes.
    Upgraded unit control board with intuitive indoor fan adjustment.
    Reliable copper tube / aluminum fin condenser coil with 5/16-in. tubing to help reduce refrigerant charge versus prior designs.
    New outdoor fan system with rugged, lightweight high impact composite fan blade.
    Installation ease
    All RGV/RAV units are field convertible to horizontal air flow, which makes it easy to adjust to unexpected job site complications. RGV/RAV rooftop units up to 6 tons are specifically designed to fit on our existing roof curbs dating back to 1989 for worry-free original fit. Also, our large control box gives you room to work and room to mount accessory controls. Intuitive controls make setting up the required fan speed simple and accurate. Access to the blower section is no longer needed with the new design.
    Easy to maintain
    with the new Vane Axial fan and direct drive ECM motor, there is no longer a need to adjust belts or pulleys as in past designs. This frees up maintenance and installation time.
    Easy access handles provide quick and easy access to all normally serviced components. Our “no-strip” screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s metal. Sloped, corrosion resistant composite drain pan sheds water and won’t rust. RGV units are designed with a naturally draining heat exchanger. Unlike positive pressure heat exchangers, this does not need to be periodically, manually drained. This saves labor and maintenance expense.
    Easy to use
    The newly re-designed Unit Control Board puts all connections and troubleshooting points in one convenient place. Most low voltage connections are made to the same board for easy access. Setting up the fan is made simple by an intuitive switch and rotary dial arrangement. RGV/RAV rooftops have high and low pressure switches, a filter drier, and 2-in. filters standard.
    X-Vane Fan Technology
    Direct drive X-Vane Fan Technology indoor fan system uses vane axial fan design and electrically commutated motors. This new Vane Axial design over past belt drive systems has 75% fewer moving parts, uses up to 40% less energy and has no fan belts, blower bearings, or shaft.
    Design features include:
    Single-stage units deliver SEERs up to 14.0 and EERs up to 11.8. Two-stage units deliver IEERs up to 15.2 and EERs up to 11.2.
    All models are capable of either vertical or horizontal airflow.
    RGV/RAV rooftop units (RTU) were designed by customers for customers. with “no-strip” screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton RGV/RAV rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. RGV/RAV Product Specifications
    Features/Benefits Value-added features include:
    Optional Hot Gas Re-Heat dehumidification system for improved part load humidity performance
    R-410A refrigerant
    Single point gas and electrical connections
    3 to 5 ton models use fixed refrigerant metering devices and 6 ton models use a TXV
    Scroll compressors with internal line-break overload protection
    Operating efficiency and flexibility
    The RGV/RAV rooftops exceed ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers) 90.1-2016, IECC1 (International Energy Conservation Code) IECC-2018 minimum efficiency requirements.
    Field convertible airflow
    All RGV/RAV 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unexpected job site complications.
    Comfort control
    Our patented Hot Gas Re-Heat dehumidification system is an all-inclusive factory-installed option on gas heating/electric cooling and electric cooling/electric heat models. This system provides reliable, flexible operation to meet indoor part load sensible and latent requirements.
    Features and Specification
    Weight
    511
    AHRI - Usage
    Packaged
    Air Flow Direction
    Convertible
    Blower Motor HP
    1 11/25 HP
    Blower Motor RPM
    239-2390
    Blower Motor Speeds
    Variable
    Blower Motor Type
    ECM (Electronically Commutated Motor)
    Blower Wheel Size
    16 3/5
    Brand
    Tempstar
    CBU - Compressor Bearing Unit
    Yes
    CFM Cooling
    1500-2500
    Compressor
    Scroll
    Condenser Motor HP
    1/4 HP
    Condenser Motor RPM
    1100
    Condenser Motor Speeds
    1 (Single)
    Condenser Motor Type
    Direct Drive
    Cooling Capacity
    58500
    Cubic Measurement
    66.9766
    Cycle/Hertz
    60 Hz
    Drain Connection Quantity
    1
    Drain Connection Size
    3/4
    Drive Type
    Direct
    EER
    11.2
    Electric Heat Range [kW]
    0
    Energy Star Rated
    No
    Equipment Type
    Straight Cool
    Evaporator Coil Metering Device
    Accutrol - Fixed Metering Device
    Fan Diameter
    23
    Filter Size
    (2) 16" x 25" x 2" RA Filter, (1) 20" x 24" x 1" OA Inlet Screen
    Height
    33.375
    Length
    46.625
    Locked Rotor Amps (LRA)
    110
    Number of Fan Blades
    1
    OPT Code
    1PRAV060H0FA0AAA
    Phase
    Three
    Package Weight
    551
    Product Family
    RAV
    Prop 65
    Yes
    Rated Load Amps (RLA)
    16
    Refrigerant
    R-410A
    Sound Level (dBA)
    79-85.6
    Stage
    Single
    Tonnage
    5
    UL Listed
    Yes
    UOM
    EA
    UPC
    See Optical
    Voltage
    208-230 VAC
    Width
    74.375
    Maximum Overcurrent Protection (MOCP)
    45